Webasto Thermo Test Setup

From DISCO3.CO.UK Knowledge Base
Revision as of 22:44, 22 February 2016 by Martin (talk | contribs) (Adapter Configuration)
Jump to: navigation, search

This is a brief guide to setting up the Webasto Thermo Test (WTT) software.

NOTE! The Thermo Test software is compatible with Windows ONLY. There is no OSX or Linux version.

It has been confirmed to work on Windows running on a Macbook.

Adapter Installation

This guide covers setting up using the widely available "VAG KKL"/"KKL VAG COM for 409.1" adapter.

The adapters currently available are generally dark translucent blue in colour and contain the CH340G adapter chip.

Some older or more expensive adapters may use the FTDI FT232 adapter chip.

There is no functional difference between the two chips as far as the Thermo Test software is concerned.

The only difference is which driver you may need to download for Windows versions prior to Windows 7.

Drivers

Drivers for the CH340G and FT232 chips are built into Windows from Windows 7 onwards.

Older versions of Windows will require a driver downloading and installing.

These are links to the manufacturers' driver download sites:

Your adapter may also have been supplied with the drivers on CD.

Connect your adapter to a free USB port on your laptop (it will be helpful later if you always use the same USB port every time you connect the adapter).

Windows should either automatically install a driver (Windows 7 and later) or prompt you for one (Vista and earlier).

Allow the driver installation to complete.

Adapter Configuration

The WTT software only works with COM port numbers less than 20. Often the COM port selected when an adapter is installed is higher than this, so we need to change it.

Open "Device Manager" as follows:

  • Open the Run window by pressing and holding the Windows key on the keyboard, then tap the R key
  • Type devmgmt.msc and press the "OK" button

msrun00.gif

Device Manger should open:

wtt01.gif

Now find the adapter device and change its settings:

  • Click the triangle next to "Ports (COM & LPT)"

wtt02.gif

  • Right click on "USB-SERIAL CH340 (COMnn)" [nn is a variable number] and click "Properties"
    • Note that an FTDI FT232RL based adapter will be called "USB Serial Port (COMnn)"

wtt03.gif

  • Click on the "Port Settings" tab

wtt04.gif

  • Click on the "Advanced" button

wtt05.gif

  • From the drop-down list, select a COM port less than 20. To avoid possible conflicts with hardware serial ports, a number greater than 3 is best - e.g. COM5 as shown.
    • Note that an FTDI FT232RL based adapter has this list at the top of the window

wtt06.gif

  • If possible pick a port without "(in use)" against it. But if you have no COM port between 3 and 19 without "(in use)" next to it then do not worry, it does not normally cause a problem to pick one with "(in use)" against it.
  • Make a note of the COM port - you will need it to set up WTT
  • Click the "OK" button

wtt07.gif

  • Close the device properties using the red cross

wtt08.gif

  • Close Device Manager using the red cross

wtt09.gif

  • Unplug your USB adapter and plug it back into the same USB port. I find this helps WTT find your adapter with its new COM port.

Your adapter is now ready for use with WTT.

Software Installation

Download the software (and manual) from Fuel Burning Heater#Thermo_Test_Software

Run the installer and install the software using the default options. A more comprehension guide is in the manual, pages 14 and 15 (ignore the part about connecting the adapter at the end of page 15).

Once installed the Webasto Thermo Test software is available in the Start Menu. It is in the "Webasto Thermo Test" folder, then "WTT" icon.

Configuring the software

You can now start the WTT software from the Start Menu icon as above.

Before attempting to use the software you should configure it.

  • From the "Extras" menu select "COM port...".

wtt10.gif

  • Select the COM port you selected in the adapter configuration above and click the "OK" button

wtt11.gif

  • From the "Diagnosis" menu select "Device selection..."

wtt12.gif

  • Now select "W-Bus" and click the "OK" button

wtt13.gif

WTT should now be configured ready to use.

Using Webasto Thermo Test

When you use WTT in the future you can start from this point!

wtt14.gif

  • The WTT software will now connect to the FBH and undertake status and fault code reading.

Troubleshooting

More coming soon - if you need help please ask on the forum!

No connection to the FBH

  • Double check your connections from the OBD adapter to the FBH.
  • Make sure the power LED is lit on the OBD adapter

If you have made a loom yourself, try both pin 4 and pin 5 of the OBD adapter for the ground connection to the battery as some OBD adapters are wired to one or the other and not both.

The DISCO3 site shop loom bridges pins 4 and 5: http://www.disco3.co.uk/shop/fbh-diagnostic-loom-lead-for-webasto-p66.html

You could also modify the OBD adapter lead internally to bridge pins 4 and 5 together.

Attention! The selected COM port cannot be used!

This window appears roughly infinity times if the "Automatic start" option has been selected in WTT and the software cannot find the COM port you have selected.

wtterr01.gif

If it does it on starting WTT it locks up WTT and you cannot access the "Extras" menu to switch it off.

To fix this:

  • Download and apply this registry file:

http://media.disco3.co.uk/misc/wtt_autostart_off.reg

  • Double click the file. Windows will ask "Do you want to allow the following program to make changes....". Click Yes.
  • Windows will then ask "Adding information can unintentionally change or delete values...". Click Yes.
  • On the confirmation window, click OK.
  • Now start WTT again. DO NOT SELECT THE AUTOSTART OPTION AGAIN!!

Incorrect/missing COM port

If you use a different USB port for your adapter to the one you first used when setting it up, it may be issued a different COM port number.

If this COM port number is greater than 19 then WTT will not see it.

You should close WTT, then follow the #Driver_Configuration section above to re-set the COM port number to one less than 20.

Unplug the USB plug for the adapter, plug it in again (it will remember its COM port number) and then restart WTT.